FG-LL30+ up to 200m

Automatic Zenith Laser Plummet

The Automatic Laser Plummet FG-LL30+ is a 2 axis electronic self-leveling laser and can be used for zenith plumbings for distances up to 200 meters. It provides an accuracy of ± 5 mm per 100 meters.

Article number: 100356:533.22

Downloads

Accuracy Mean error ± 5 mm per 100 m
Laser Laser class 2
Output < 1 mW
Laser Diode, visible red
635 nm
Range   up to 200 m
Operating time   up to 60h
Power supply   from 11 V to 14V DC
Low voltage switch off   yes
waterproof IPC67   max depth 3.5 m
Temperature range   -10°C ... + 50°C
Weight FG-LL30+ 3.4 kg
  • exact positioning of building elements, zenith plumbings
  • transferring reference points upwards
  • integration of reference points into the plumb line
  • verification of deviations from the plumb line
  • used for the erection of high-rise buildings, smoke stacks, shafts, bridges and steel buildings
  • special measurement tasks in industrial surveying and mine surveying
  • monitoring deformation processes at buildings
  • impact-resistant carrying case, material: plastic
  • each model is also available with increased accuracy: ± 2.5mm / 100m
  • trivet mount (article no.: 100356:501.28)
  • power plug adapter for GB, USA, Australia (article no.: 108003:001.28, 108003:002.28, 108003:003.28)

The Automatic Laser Plummet FG-LL30+ is a 2 axis electronic self-leveling laser and can be used for zenith plumbings for distances up to 200 meters. It provides an accuracy of ± 5 mm per 100 meters.

Article number: 100356:533.22

Downloads

Accuracy Mean error ± 5 mm per 100 m
Laser Laser class 2
Output < 1 mW
Laser Diode, visible red
635 nm
Range   up to 200 m
Operating time   up to 60h
Power supply   from 11 V to 14V DC
Low voltage switch off   yes
waterproof IPC67   max depth 3.5 m
Temperature range   -10°C ... + 50°C
Weight FG-LL30+ 3.4 kg
  • exact positioning of building elements, zenith plumbings
  • transferring reference points upwards
  • integration of reference points into the plumb line
  • verification of deviations from the plumb line
  • used for the erection of high-rise buildings, smoke stacks, shafts, bridges and steel buildings
  • special measurement tasks in industrial surveying and mine surveying
  • monitoring deformation processes at buildings
  • impact-resistant carrying case, material: plastic
  • each model is also available with increased accuracy: ± 2.5mm / 100m
  • trivet mount (article no.: 100356:501.28)
  • power plug adapter for GB, USA, Australia (article no.: 108003:001.28, 108003:002.28, 108003:003.28)